Heat Pump Not Heating After Installation in GTA? 9 Fast Fixes
- For Saving
- Oct 10
- 5 min read
New heat pump, no heat? If your heat pump not heating after installation in GTA home is pushing cool air—or none at all—start with these safe, fast checks. We cover thermostat setup, airflow, defrost behaviour, and commissioning steps that commonly cause issues right after install. If temperatures still won’t climb, our licensed Ontario technicians can re-commission your system and restore steady, efficient heat across Toronto and the GTA.
Answer Capsule (Quick Wins)
Set mode to HEAT, fan to AUTO, and raise the setpoint 3–4°C above room temperature.
Let it run 10–15 minutes—defrost or soft-start staging can look like “no heat.”
Check breakers, filter, outdoor snow/ice, and that all supply/return vents are open.
If the issue began right after install, avoid repeated power-cycling—book a commissioning check.
Key Facts for GTA Homeowners
Gentle heat is normal. Heat pumps deliver steady supply temps, not furnace-like blasts.
Defrost happens. Steam or brief pauses are expected in damp, near-freezing weather.
Commissioning matters. Airflow, charge, sensor calibration, and balance-point setup determine real-world comfort.
Hybrid systems need logic. If you have backup strips or a furnace, staging must be enabled and wired correctly.
First Things to Confirm
Thermostat mode: Must be HEAT. Avoid “EM HEAT” unless instructed—it’s costly.
Setpoint bump: Raise target 3–4°C to trigger a solid call for heat.
Fan setting: Use AUTO; FAN “ON” can move air that feels cool between cycles.
Power path: Indoor breaker, outdoor breaker, and outdoor service disconnect must be ON.
Airflow path: New installs stir dust—replace the filter, open all supply/return grilles.
Outdoor check: Clear snow, leaves, or covers. Light steam during defrost is normal.

9 Fast Fixes (Homeowner-Friendly)
Let it actually heatModern inverters ramp gradually. Give it 10–15 minutes before judging supply temperature or room rise.
Remove airflow chokepointsDirty filter, closed vents, or crushed flex duct starve the system. Swap the filter and open every register. You should feel stronger, warmer airflow at the closest supply.
Thermostat profile & wiringNew smart stats can default to the wrong equipment type. Re-run the setup wizard so it knows you have a heat pump. If the reversing valve (O/B) logic is flipped, you’ll get cool air in HEAT—time to call a pro.
Outdoor unit iced solidFrost is fine; a block of ice is not. Gently remove snow and ensure drainage. Rapid re-icing points to defrost sensor/control or airflow issues that need a technician.
Aux/backup heat not stagingWith a big setpoint bump, backup heat should engage automatically. If it never ramps warmer, the aux stage may be disabled or miswired—book service.
Reversing valve stuckClassic symptom: cool in HEAT, warm in COOL. Don’t keep power-cycling; this is a pro-only repair.
Charge out of specUndercharge/overcharge after an install causes lukewarm supply and marathon run times. Only a licensed tech can measure superheat/subcool and correct safely.
Commissioning not completedAirflow (CFM/ton), sensors, defrost, balance points, and lockouts must be dialled in. If commissioning was rushed, comfort suffers. We can re-commission to manufacturer spec.
Sizing or duct mismatchEven a perfect install will struggle if the unit is undersized or ducts are restrictive. Our team can verify load calculations and static pressure, then recommend adjustments.
“Heat Pump Not Heating After Installation in GTA”: Normal vs. Fault
Likely normal:
Short plumes of steam from the outdoor unit
A brief “whoosh” and pause during defrost
Supply air that’s warm-but-not-hot, with the room temperature rising steadily over time
Likely a fault:
Room temperature won’t climb after 20–30 minutes of a heating call
Supply air is consistently cool to the hand in HEAT mode
Outdoor unit ices into a block, or the stat shows heat but the outdoor unit never starts
Brand-new system started misbehaving immediately after installation

Smart Thermostat Quirks to Watch
Learning modes may throttle early. Use a temporary hold to test heating.
Balance point settings can lock out the heat pump too early or too late.
Equipment type must be “Heat Pump,” with the correct O/B setting and aux stage enabled.
Fan programming: Leave it AUTO for heating unless instructed otherwise.
GTA Climate Tips for Reliable Heat
Keep 1 metre of clearance around the outdoor unit; trim shrubs and clear snow berms.
On storm days, visually check the unit for ice and listen for normal compressor/fan sounds.
Don’t cover the outdoor unit with plastic; it traps moisture and invites ice.
What Our Technicians Check on a Call-Back
Thermostat setup, wiring, and reversing-valve logic
Static pressure, filter size, and CFM/ton airflow settings
Refrigerant charge via manufacturer tables and test conditions
Defrost sensors/board operation and outdoor fan performance
Hybrid/aux staging, lockouts, and balance points
Line set quality (length, slope, insulation) and evacuation integrity
Sensor calibration (supply/return delta, outdoor ambient reading)
This systematic approach finds whether your heat pump not heating after installation in GTA is a simple setting, a wiring oversight, or a deeper design issue.
What To Do Before We Arrive (Mini-Guide)
Snap photos of the thermostat screen and the outdoor nameplate.
Note any error codes, odours, or unusual noises.
Leave the system ON in HEAT for at least 15 minutes so we can capture live data.
Clear space around the outdoor unit and ensure the filter is fresh.
Have install paperwork ready (model/serial, install date).
Need a Re-check or a Proper Install?
If your system wasn’t installed by us—or you’re considering replacement—use our trusted local pages:
Prefer a direct GTA booking? Tap our team for quality heat pump installation
Why For Saving Home Services Inc
Licensed & insured GTA technicians; safety-compliant, code-first workmanship
Commissioning included—airflow, charge, sensors, defrost, and controls validated
Transparent options & warranties—no surprises, written quotes
Rapid response across Toronto, North York, Scarborough, Markham, Richmond Hill, Vaughan, and nearby
Customer-first process—clear communication, tidy job sites, and post-install support
FAQ
Why is my heat pump not heating after installation in GTA?
Most cases involve thermostat setup, airflow restriction, a defrost delay, or commissioning oversights (reversing-valve logic, aux stage disabled, or charge). Start with mode HEAT, fan AUTO, a 3–4°C setpoint bump, then call if room temperature won’t rise.
How long until a new heat pump delivers warm air?
Allow 10–15 minutes for modern inverters to ramp. If the room temperature hasn’t moved after 20–30 minutes, book service.
Should I use Emergency Heat in Toronto winters?
Not by default. EM Heat forces backup only and increases costs. Proper balance points let the heat pump carry most days; backup engages automatically when needed.
Why does the outdoor unit steam or pause?
That’s defrost—expected in damp, near-freezing weather. Persistent ice indicates a sensor, board, or airflow problem that needs a technician.
When should I call for help instead of DIY?
If you’ve confirmed settings, filter, breakers, and vents—yet supply air stays cool or temperatures won’t climb—call a licensed tech. Installation-related issues are warranty-sensitive and require professional instruments and commissioning steps.
Ready to get warm again?
Book Same-Day Diagnostic & Commissioning Check